Why consider it

  • Integrated motors remove external tubing and a separate motor to carry.
  • Four insert sizes accompany the 24 mm flanges, giving documented sizing options to check.

What to consider

  • The pumps cannot be used while charging; the manual specifies the supplied cables and a 5V 2A power supply.
  • The manual requires an upright position and removal of the hub before pouring milk.

Specifications

At a glance

Power
Rechargeable pump hubs; supplied USB charging cords
Milk collection
Two in-bra collectors with integrated motors; 6 oz each
Fit options
24 mm flanges; 15, 17, 19 and 21 mm inserts
Pumping options
Double kit; settings adjustable separately per breast
Modes
Stimulation, expression, massage and automatic
Adjustment
Nine suction levels per mode
What comes with it
The Flow kit includes two collectors, 24 mm flanges, 15, 17, 19 and 21 mm inserts, USB charging cords, bra extenders and a sizing ruler.
Fit & feel
Four insert sizes and bra extenders offer adjustment options for the cup setup; each side has its own suction controls.

Details, care & buying

Full specifications & kit details

Power
Rechargeable pump hubs; supplied USB charging cords
Milk collection
Two in-bra collectors with integrated motors; 6 oz each
Fit options
24 mm flanges; 15, 17, 19 and 21 mm inserts
Pumping options
Double kit; settings adjustable separately per breast
Modes
Stimulation, expression, massage and automatic
Adjustment
Nine suction levels per mode
Kit extras
Bra extenders, nipple ruler and USB charging cords

Kit & specification notes

This is Flow, not the original DiscreetDuo or the separate Lansinoh Wearable Pump. Lansinoh warns that original DiscreetDuo extra parts are not interchangeable with Flow; verify every replacement part. Runtime is omitted because the sales page and linked manual give different figures. Keep the pump upright as instructed; the collection cups are not spill-proof in every position.

Manufacturer-listed specifications checked . Lansinoh product details ↗

Set up the Flow for a session

Each side has its own motor and controls. Check both batteries and start with clean, fully dry collection pieces.

  1. Attach the valve horizontally. Fit the diaphragm with its notch facing the flange/breast side, then press its rim firmly into place.
  2. Align the pour spouts, press the flange firmly around its entire edge and close the spout cover.
  3. Align the underside of the motor hub with the diaphragm and press it into an airtight connection. Keep the pump upright and steady in your bra.

If suction seems weak or absent, check the charge, component orientation and complete flange seal before changing settings. Stop if pumping hurts; seek qualified help for pain or feeding concerns.

Sources: Lansinoh Flow setup and suction guidance; Flow assembly instructions.

Finish the session and transfer milk

Have a milk-storage container ready before removing the pumps:

  1. Turn the pump off and release the breast seal gently with a finger.
  2. Keep it upright while taking it out of your bra, then remove the motor hub before tilting it to pour.
  3. Pour through the slot at the top of the collection cup, keeping the flange tunnel facing up.

Label and store the milk using the fresh and thawed milk limits. In-bra collection still requires somewhere to transfer milk and handle used equipment.

Sources: Lansinoh Flow milk-transfer guidance; Flow after-pumping instructions.

Clean, dry and recharge for the next session

Wash the collection pieces
Keep the motor hub out of water. Rinse washable pieces in cold water after use, then hand-wash in warm soapy water in a dedicated basin. A brush may be used on hard plastic, but not on silicone pieces.
Dry before packing
Rinse with clean water and let the pieces air-dry fully without rubbing them dry. Do not assemble or seal damp pieces in a bag. Flow's care instructions prohibit microwave disinfection.
Charge between uses
The pumps cannot operate while charging. Use the supplied cables with a 5V 2A supply; do not use fast-charge cables or adapters. Check each hub's charge before relying on it for another session.

For repeated sessions away from home, allow drying time or bring a complete clean, dry collection set for each side you will use. Extra inserts alone do not make a complete set. See the cleaning routine and complete-kit inventory.

Source: Lansinoh Flow US care and charging instructions. Assembly, transfer, care and charging checked . This scoped check does not recheck runtime, kit contents or every specification.

Before you order

Compare the exact kit, compatible spare parts, return terms and warranty for your seller. Use the cost planner to include any extras you need. If using a US plan, start with the insurance checklist.

View manufacturer details

Manufacturer videos

Lansinoh Discreet Duo Flow Assembly

Official manufacturer demonstration; follow the instructions supplied with your exact model.

Watch on YouTube ↗ · Manufacturer source ↗ · Checked

How to use Discreet Duo Flow

Official manufacturer demonstration; follow the instructions supplied with your exact model.

Watch on YouTube ↗ · Manufacturer source ↗ · Checked

Loading a video connects to YouTube or the manufacturer’s video host, whose privacy terms apply. No player connects until you press its load button.

Instructions & support

Sources & further reading

Sources checked . Product packages and guidance can change.

Overview checked October 8, 2026; kit and fit details checked October 8, 2026. By Breast Pump Clarity. These scoped checks do not recheck every specification.